plugins/hal-zwave/resources/config/act/lfm20.xml
Normal file
4
plugins/hal-zwave/resources/config/act/lfm20.xml
Normal file
|
|
@ -0,0 +1,4 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
||||
<Protocol nodeinfosupported="false" />
|
||||
</Product>
|
||||
93
plugins/hal-zwave/resources/config/act/zdm230.xml
Normal file
93
plugins/hal-zwave/resources/config/act/zdm230.xml
Normal file
|
|
@ -0,0 +1,93 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
||||
<!-- Configuration Parameters -->
|
||||
<CommandClass id="112">
|
||||
<Value type="list" index="1" genre="config" label="Ignore Start-Level (Transmitting)" value="1">
|
||||
<Help>Dimmers controlled by this switch will start dimming from their current level.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="2" genre="config" label="Suspend Group 4" value="0">
|
||||
<Help>Disable transmitting commands to Z-Wave devices that are in Group 4 without disassociating those devices from the group.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="3" genre="config" label="Night Light" value="0">
|
||||
<Help>In night-light mode the LED on the switch will turn ON when the switch is turned OFF.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="4" genre="config" label="Invert Switch" value="0">
|
||||
<Help>Change the top of the switch to OFF and the bottom of the switch to ON. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="5" genre="config" label="Ignore Start-Level (Receiving)" value="1">
|
||||
<Help>This dimmer will start dimming from its current level.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="6" genre="config" label="Don't Send Level After Dim" value="1">
|
||||
<Help>When you press and hold the bottom of the ZDM230 switch once, the Z-Wave devices that are associated into Group 1 are sent the Dim command. If this parameter is set to "Yes" the devices in Group 1 will not go to the same level as the ZDM230.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="byte" index="7" genre="config" label="On/Off Command Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="8" genre="config" label="On/Off Command Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="9" genre="config" label="Local Control Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="10" genre="config" label="Local Control Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="11" genre="config" label="ALL ON/ALL OFF Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="12" genre="config" label="ALL ON/ALL OFF Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="list" index="13" genre="config" label="Disable Group 4 During Dim">
|
||||
<Help>Units in Group 4 only track when the dimmer is being turned ON and OFF and not while dimming.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="14" genre="config" label="Enable Shade Control Group 2" value="0">
|
||||
<Help>The ZDM230 can operate shade control devices via its group 2.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="15" genre="config" label="Enable Shade Control Group 3" value="0">
|
||||
<Help>The ZDM230 can operate shade control devices via its group 3.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="19" genre="config" label="LED Transmission Indication" value="2">
|
||||
<Help>The ZDM230 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting.</Help>
|
||||
<Item label="None" value="0" />
|
||||
<Item label="While Transmitting" value="1" />
|
||||
<Item label="One Second Maximum" value="2" />
|
||||
</Value>
|
||||
<Value type="byte" index="20" genre="config" label="Poll Group 2 Interval" units="minutes" min="1" max="255" value="2">
|
||||
<Help>Poll Group 2 Interval</Help>
|
||||
</Value>
|
||||
<Value type="list" index="22" genre="config" label="Enable Group 2 Polling">
|
||||
<Help>Poll Group 2</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
</CommandClass>
|
||||
|
||||
<!-- Association Groups -->
|
||||
<CommandClass id="133">
|
||||
<Associations num_groups="4">
|
||||
<Group index="1" max_associations="5" label="Left Switch" />
|
||||
<Group index="2" max_associations="5" label="Right Switch" />
|
||||
<Group index="3" max_associations="5" label="Right Switch (2 Taps)" />
|
||||
<Group index="4" max_associations="5" label="Update Controller" auto="true" />
|
||||
</Associations>
|
||||
</CommandClass>
|
||||
</Product>
|
||||
69
plugins/hal-zwave/resources/config/act/zdw103.xml
Normal file
69
plugins/hal-zwave/resources/config/act/zdw103.xml
Normal file
|
|
@ -0,0 +1,69 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
||||
<!-- Configuration Parameters -->
|
||||
<CommandClass id="112">
|
||||
<Value type="list" index="1" genre="config" label="Ignore Start-Level (Transmitting)" value="1">
|
||||
<Help>Dimmers controlled by this switch will start dimming from their current level.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="3" genre="config" label="Night Light" value="0">
|
||||
<Help>In night-light mode the LED on the switch will turn ON when the switch is turned OFF.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="4" genre="config" label="Invert Switch" value="0">
|
||||
<Help>Change the top of the switch to OFF and the bottom of the switch to ON.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="5" genre="config" label="Ignore Start-Level (Receiving)" value="1">
|
||||
<Help>This dimmer will start dimming from its current level.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="byte" index="7" genre="config" label="On/Off Command Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="8" genre="config" label="On/Off Command Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="9" genre="config" label="Local Control Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="10" genre="config" label="Local Control Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="11" genre="config" label="ALL ON/ALL OFF Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="12" genre="config" label="ALL ON/ALL OFF Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="list" index="14" genre="config" label="Enable Shade Control Group 2" value="0">
|
||||
<Help>The ZDW103 can operate shade control devices via its group 2.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="15" genre="config" label="Enable Shade Control Group 3" value="0">
|
||||
<Help>The ZDW103 can operate shade control devices via its group 3.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="19" genre="config" label="LED Transmission Indication" value="2">
|
||||
<Help>The ZDW103 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting.</Help>
|
||||
<Item label="None" value="0" />
|
||||
<Item label="While Transmitting" value="1" />
|
||||
<Item label="One Second Maximum" value="2" />
|
||||
</Value>
|
||||
</CommandClass>
|
||||
|
||||
<!-- Association Groups -->
|
||||
<CommandClass id="133">
|
||||
<Associations num_groups="3">
|
||||
<Group index="1" max_associations="5" label="Group 1" />
|
||||
<Group index="2" max_associations="5" label="Group 2 (two taps)" />
|
||||
<Group index="3" max_associations="5" label="Group 3 (three taps)" />
|
||||
</Associations>
|
||||
</CommandClass>
|
||||
</Product>
|
||||
112
plugins/hal-zwave/resources/config/act/zdw232.xml
Normal file
112
plugins/hal-zwave/resources/config/act/zdw232.xml
Normal file
|
|
@ -0,0 +1,112 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
||||
<!-- Configuration Parameters -->
|
||||
<CommandClass id="112">
|
||||
<Value type="list" index="1" genre="config" label="Set Ignore Start Level Bit When Transmitting Dim Commands" value="1">
|
||||
<Help>
|
||||
The ZDW232 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level embedded
|
||||
in it. A dimmer receiving this command will start dimming from that start level. However, the command also has a
|
||||
bit that indicates whether the dimmer should ignore the start level. If the bit is set to 1, the dimmer will ignore the
|
||||
start level and instead start dimming from its current level. If this bit is set to 0, the dimmer will not ignore the start
|
||||
level.
|
||||
</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="2" genre="config" label="Suspend Group 4" value="0">
|
||||
<Help>You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without "un-associating"
|
||||
those devices from the group. Setting parameter 2 to the value of 1 will stop the ZDW232 from transmitting to devices
|
||||
that are "associated" into Group 4.
|
||||
It is possible that you may only want the units in Group 4 to track when the dimmer is being turned ON and OFF
|
||||
and not when dimming.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="3" genre="config" label="Night Light" value="0">
|
||||
<Help>In night-light mode the LED on the switch will turn ON when the switch is turned OFF.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="4" genre="config" label="Invert Switch" value="0">
|
||||
<Help>To change the top of the switch to OFF and the bottom of the switch to ON, set parameter 4 to 1.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="5" genre="config" label="Ignore Start Level When Receiving Dim Commands" value="1">
|
||||
<Help>The ZDW232 can be set to ignore the start level that is part of the dim command, regardless of whether the command
|
||||
is telling the dimmer to ignore the start level or not ignore the start level embedded in the command (see Parameter
|
||||
1). Setting parameter 5 to a value of 1 (factory default) will cause the ZDW232 to ignore the start level and to dim
|
||||
or brighten from its current level. Setting the value to 0 will cause the ZDW232 to dim or brighten from the level in
|
||||
the command.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="6" genre="config" label="Don't Send Level Command After Transmitting Dim Commands" value="1">
|
||||
<Help>When you press and hold the bottom of the ZDW232 switch once, the Z-Wave devices that areassociated into Group
|
||||
1 are sent the Dim command. If parameter 6 is set to 0, after you release the switch, the ZDW232 will command
|
||||
devices in that group to go to the same level of the ZDW232. If parameter 6 is set to a value of 1 (factory default)
|
||||
the devices in Group 1 will not go to the same level of the ZDW232.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="byte" index="7" genre="config" label="On/Off Command Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="8" genre="config" label="On/Off Command Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="9" genre="config" label="Local Control Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="10" genre="config" label="Local Control Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="11" genre="config" label="ALL ON/ALL OFF Dim Step" units="" min="1" max="99" value="1">
|
||||
<Help>Indicates how many levels the dimmer will change for each dimming step.</Help>
|
||||
</Value>
|
||||
<Value type="byte" index="12" genre="config" label="ALL ON/ALL OFF Dim Rate" units="x 10 milliseconds" min="1" max="255" value="3">
|
||||
<Help>This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dim level will change.</Help>
|
||||
</Value>
|
||||
<Value type="list" index="13" genre="config" label="Disable Group 4 During Dim">
|
||||
<Help>After the ZDW232 is commanded to stop dimming, it will then command the Z-Wave devices in Group 4 to the
|
||||
ZDW232's new level. To prevent the ZDW232 from commanding the Z-Wave devices in Group 4 during this particular
|
||||
occurrence, set Parameter 13 to the value of 1.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="14" genre="config" label="Enable Shade Control Group 2" value="0">
|
||||
<Help>The ZDW232 can operate shade control devices via its group 2 if this configuration parameter is set to 1.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="15" genre="config" label="Enable Shade Control Group 3" value="0">
|
||||
<Help>The ZDW232 can operate shade control devices via its group 3 if this configuration parameter is set to 1.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="19" genre="config" label="LED Transmission Indication" value="2">
|
||||
<Help>The ZDW232 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting.</Help>
|
||||
<Item label="None" value="0" />
|
||||
<Item label="While Transmitting" value="1" />
|
||||
<Item label="One Second Maximum" value="2" />
|
||||
</Value>
|
||||
<Value type="byte" index="20" genre="config" label="Poll Group 2 Interval" units="minutes" min="1" max="255" value="2">
|
||||
<Help>Poll Group 2 Interval</Help>
|
||||
</Value>
|
||||
<Value type="list" index="22" genre="config" label="Enable Group 2 Polling">
|
||||
<Help>Poll Group 2</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
</CommandClass>
|
||||
|
||||
<!-- Association Groups -->
|
||||
<CommandClass id="133">
|
||||
<Associations num_groups="4">
|
||||
<Group index="1" max_associations="5" label="One tap / Local load control" />
|
||||
<Group index="2" max_associations="5" label="Two taps (Dimmers: One tap, then hold to dim)" />
|
||||
<Group index="3" max_associations="5" label="Three taps (Dimmers: Two taps, then hold to dim)" />
|
||||
<Group index="4" max_associations="5" label="Update Controller" auto="true" />
|
||||
</Associations>
|
||||
</CommandClass>
|
||||
</Product>
|
||||
63
plugins/hal-zwave/resources/config/act/zir010.xml
Normal file
63
plugins/hal-zwave/resources/config/act/zir010.xml
Normal file
|
|
@ -0,0 +1,63 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
||||
<!-- Configuration Parameters -->
|
||||
<CommandClass id="112">
|
||||
<Value type="list" index="17" genre="config" label="Mode" value="0" size="1">
|
||||
<Help>
|
||||
The ZIR010 can be configured to operate in 1 of 3 modes.
|
||||
Those modes are:
|
||||
Lighting Mode (factory default)
|
||||
Alarm Mode
|
||||
Sensor Mode
|
||||
To change the mode of operation:
|
||||
For Lighting Mode: Send a value of 0 to Configuration Parameter #17.
|
||||
For Alarm Mode: Send a value of 1 to Configuration Parameter #17.
|
||||
For Sensor Mode: Send a value of 2 to Configuration Parameter # 17.
|
||||
Information reproduced from: http://www.pepper1.net/zwavedb/uploads/resources/bdf086a9388325a2fb8b8aa298e24e512faec65d.pdf
|
||||
</Help>
|
||||
<Item label="Lighting" value="0" />
|
||||
<Item label="Alarm" value="1" />
|
||||
<Item label="Sensor" value="2" />
|
||||
</Value>
|
||||
<Value type="byte" index="18" genre="config" label="Off/Idle Delay" units="minutes" min="0" max="255" value="1">
|
||||
<Help>
|
||||
The configuration parameter that can be used to adjust the amount of delay before the OFF or IDLE command is transmitted is Configuration Parameter # 18.
|
||||
This parameter can be configured with the value of 0 through 255.
|
||||
Where 0 means no delay and 255 means 255 minutes of delay.
|
||||
Default appears to be 1 min.
|
||||
Information reproduced from: http://www.pepper1.net/zwavedb/uploads/resources/bdf086a9388325a2fb8b8aa298e24e512faec65d.pdf
|
||||
</Help>
|
||||
</Value>
|
||||
<Value type="list" index="19" genre="config" label="Unsolicited Commands" value="1" size="1">
|
||||
<Help>
|
||||
The ZIR010 can be disabled from sending commands unsolicited without removing associated devices by
|
||||
setting Configuration Parameter # 19 to 0 (when asked for number of bytes, select 1).
|
||||
Setting it back to 1 will re-enable the ZIR010.
|
||||
Information reproduced from: http://www.pepper1.net/zwavedb/uploads/resources/bdf086a9388325a2fb8b8aa298e24e512faec65d.pdf
|
||||
</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="byte" index="22" genre="config" label="Awake Time" units="seconds" min="15" max="45" value="30">
|
||||
<Help>
|
||||
The time the ZIR010 stays awake can be adjusted from 15 seconds to 45 seconds by sending a value of 15
|
||||
to 45 to the ZIR010 using Configuration Parameter # 22 (when asked for the number of bytes, select 1).
|
||||
This awake time period starts over every time the ZIR010 receives a command or request.
|
||||
Defaults to 30 seconds.
|
||||
Information reproduced from: http://www.pepper1.net/zwavedb/uploads/resources/bdf086a9388325a2fb8b8aa298e24e512faec65d.pdf
|
||||
</Help>
|
||||
</Value>
|
||||
</CommandClass>
|
||||
|
||||
<!-- Basic set as report -->
|
||||
<CommandClass id="32" setasreport="true"/>
|
||||
<!-- Association Groups -->
|
||||
<CommandClass id="133">
|
||||
<Associations num_groups="3">
|
||||
<Group index="1" max_associations="5" label="Motion" auto="true"/>
|
||||
<Group index="2" max_associations="5" label="Tamper" />
|
||||
<Group index="3" max_associations="5" label="Battery" auto="true" />
|
||||
</Associations>
|
||||
</CommandClass>
|
||||
</Product>
|
||||
|
||||
7
plugins/hal-zwave/resources/config/act/zrp110.xml
Normal file
7
plugins/hal-zwave/resources/config/act/zrp110.xml
Normal file
|
|
@ -0,0 +1,7 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
||||
<!-- Configuration Parameters -->
|
||||
<CommandClass id="112">
|
||||
<Value type="bool" index="29" genre="config" label="Load Sense" units="" min="0" max="1" />
|
||||
</CommandClass>
|
||||
</Product>
|
||||
36
plugins/hal-zwave/resources/config/act/zrw103.xml
Normal file
36
plugins/hal-zwave/resources/config/act/zrw103.xml
Normal file
|
|
@ -0,0 +1,36 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
||||
<!-- Configuration Parameters -->
|
||||
<CommandClass id="112">
|
||||
<Value type="list" index="1" genre="config" label="Ignore Start-Level (Transmitting)" value="1">
|
||||
<Help>Dimmers controlled by this switch will start dimming from their current level.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="3" genre="config" label="Night Light" value="0">
|
||||
<Help>In night-light mode the LED on the switch will turn ON when the switch is turned OFF.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="4" genre="config" label="Invert Switch" value="0">
|
||||
<Help>Change the top of the switch to OFF and the bottom of the switch to ON.</Help>
|
||||
<Item label="No" value="0" />
|
||||
<Item label="Yes" value="1" />
|
||||
</Value>
|
||||
<Value type="list" index="19" genre="config" label="LED Transmission Indication" value="2">
|
||||
<Help>The ZRW103 will flicker its LED when it is transmitting to any of its 4 groups. This flickering can be set to not flicker at all, to flicker the entire time it is transmitting, or to flicker for only 1 second when it begins transmitting.</Help>
|
||||
<Item label="None" value="0" />
|
||||
<Item label="While Transmitting" value="1" />
|
||||
<Item label="One Second Maximum" value="2" />
|
||||
</Value>
|
||||
</CommandClass>
|
||||
|
||||
<!-- Association Groups -->
|
||||
<CommandClass id="133">
|
||||
<Associations num_groups="3">
|
||||
<Group index="1" max_associations="5" label="Group 1" />
|
||||
<Group index="2" max_associations="5" label="Group 2 (two taps)" />
|
||||
<Group index="3" max_associations="5" label="Group 3 (three taps)" />
|
||||
</Associations>
|
||||
</CommandClass>
|
||||
</Product>
|
||||