63 lines
3 KiB
XML
63 lines
3 KiB
XML
<?xml version="1.0" encoding="utf-8"?>
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!-- Configuration Parameters -->
|
|
<CommandClass id="112">
|
|
<Value type="list" index="17" genre="config" label="Mode" value="0" size="1">
|
|
<Help>
|
|
The ZIR010 can be configured to operate in 1 of 3 modes.
|
|
Those modes are:
|
|
Lighting Mode (factory default)
|
|
Alarm Mode
|
|
Sensor Mode
|
|
To change the mode of operation:
|
|
For Lighting Mode: Send a value of 0 to Configuration Parameter #17.
|
|
For Alarm Mode: Send a value of 1 to Configuration Parameter #17.
|
|
For Sensor Mode: Send a value of 2 to Configuration Parameter # 17.
|
|
Information reproduced from: http://www.pepper1.net/zwavedb/uploads/resources/bdf086a9388325a2fb8b8aa298e24e512faec65d.pdf
|
|
</Help>
|
|
<Item label="Lighting" value="0" />
|
|
<Item label="Alarm" value="1" />
|
|
<Item label="Sensor" value="2" />
|
|
</Value>
|
|
<Value type="byte" index="18" genre="config" label="Off/Idle Delay" units="minutes" min="0" max="255" value="1">
|
|
<Help>
|
|
The configuration parameter that can be used to adjust the amount of delay before the OFF or IDLE command is transmitted is Configuration Parameter # 18.
|
|
This parameter can be configured with the value of 0 through 255.
|
|
Where 0 means no delay and 255 means 255 minutes of delay.
|
|
Default appears to be 1 min.
|
|
Information reproduced from: http://www.pepper1.net/zwavedb/uploads/resources/bdf086a9388325a2fb8b8aa298e24e512faec65d.pdf
|
|
</Help>
|
|
</Value>
|
|
<Value type="list" index="19" genre="config" label="Unsolicited Commands" value="1" size="1">
|
|
<Help>
|
|
The ZIR010 can be disabled from sending commands unsolicited without removing associated devices by
|
|
setting Configuration Parameter # 19 to 0 (when asked for number of bytes, select 1).
|
|
Setting it back to 1 will re-enable the ZIR010.
|
|
Information reproduced from: http://www.pepper1.net/zwavedb/uploads/resources/bdf086a9388325a2fb8b8aa298e24e512faec65d.pdf
|
|
</Help>
|
|
<Item label="No" value="0" />
|
|
<Item label="Yes" value="1" />
|
|
</Value>
|
|
<Value type="byte" index="22" genre="config" label="Awake Time" units="seconds" min="15" max="45" value="30">
|
|
<Help>
|
|
The time the ZIR010 stays awake can be adjusted from 15 seconds to 45 seconds by sending a value of 15
|
|
to 45 to the ZIR010 using Configuration Parameter # 22 (when asked for the number of bytes, select 1).
|
|
This awake time period starts over every time the ZIR010 receives a command or request.
|
|
Defaults to 30 seconds.
|
|
Information reproduced from: http://www.pepper1.net/zwavedb/uploads/resources/bdf086a9388325a2fb8b8aa298e24e512faec65d.pdf
|
|
</Help>
|
|
</Value>
|
|
</CommandClass>
|
|
|
|
<!-- Basic set as report -->
|
|
<CommandClass id="32" setasreport="true"/>
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="3">
|
|
<Group index="1" max_associations="5" label="Motion" auto="true"/>
|
|
<Group index="2" max_associations="5" label="Tamper" />
|
|
<Group index="3" max_associations="5" label="Battery" auto="true" />
|
|
</Associations>
|
|
</CommandClass>
|
|
</Product>
|
|
|