<?xml version="1.0" encoding="UTF-8"?>
|
|
<Product xmlns="http://code.google.com/p/open-zwave/">
|
|
|
|
<!-- Configuration Parameters -->
|
|
<CommandClass id="112">
|
|
|
|
<Value type="byte" instance="1" index="2" genre="config" label="2. Basic Set Level" min="1" max="255" value="255">
|
|
<Help>
|
|
Setting the BASIC command value to turn on the light. The 0xFF (255) means turn on the light.
|
|
For dimmer equipment 1 to 100 means the light strength.
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" instance="1" index="3" genre="config" label="3. PIR Sensitivity" min="0" max="99" value="70">
|
|
<Help>
|
|
PIR sensitivity settings.
|
|
0 means disable the PIR motion.
|
|
1 means the lowest sensitivity.
|
|
99 means the highest sensitivity.
|
|
High sensitivity means can detect long distance, but if there is more noise signal in the environment, it will re-trigger too frequently.
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" instance="1" index="4" genre="config" label="4. Light threshold" min="0" max="100" value="99">
|
|
<Help>
|
|
Setting the illummination threshold to turn on the light. When the event triggered and the environment illumination lower then
|
|
the threshold, the device will turn on the light.
|
|
0 means turn off illumination detected function and never turn on the light.
|
|
1 means darkest.
|
|
99 means brightest.
|
|
100 means turn off illumination detected function. And always turn on the light.
|
|
* Notice * in none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value.
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" instance="1" index="5" genre="config" label="5. Operation Mode" min="0" max="127" value="0">
|
|
<Help>
|
|
Bit 0: 1 means security mode; 0 means home automation mode.
|
|
Bit 1: 1 means enable test mode; 0 means disable test mode
|
|
* Notice * Bit 0 and bit 1 will effect when the DIP Switch setting to program mode. If bit1 is enabled, the bit0 is useless.
|
|
Bit 2: Reserved, always 1.
|
|
Bit 3: Setting the temperature scale; 0: Fahrenheit, 1:Celsius
|
|
Bit 4: Disable illumination report after event triggered.
|
|
Bit 5: Disable temperature report after event triggered
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" instance="1" index="6" genre="config" label="6. Multi-Sensor Function Switch" min="0" max="127" value="4">
|
|
<Help>
|
|
Multi-Sensor Function switch. Using bit to control.
|
|
Bit 0: Reserved, always 1.
|
|
Bit 1: Disable PIR integrate Illumination.
|
|
Bit 2: Reserved, always 1.
|
|
Bit 3: Reserved.
|
|
Bit 4: Reserved.
|
|
Bit 5: Reserved.
|
|
Bit 6: Enable temperature monitoring. When this bit enabled, the temperature changed 3 degree Fahrenheit, it will report.
|
|
And also the temperature over 140 degree Fahrenheit, it will report every 64 seconds.
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" instance="1" index="8" genre="config" label="8. PIR re-detect interval time" units="8 sec" min="3" max="27" value="3">
|
|
<Help>
|
|
In the security mode, after the PIR report motion detected, setting the re-detect time. 8 seconds per tick, and minimum time is 24 seconds, default tick is 3 (24 seconds).
|
|
Setting the suitable value to prevent received the trigger signal too frequency. Also can save the battery energy.
|
|
* Notice * If this value bigger than the configuration setting NO. 9. There is a period after the light turned off and the PIR not detecting.
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" instance="1" index="9" genre="config" label="9. Turn Off Light Time" units="8 sec" min="4" max="127" value="4">
|
|
<Help>
|
|
After turn on the light, setting the delay time to turn off the light when the PIR motion is not detected.
|
|
8 seconds per tick, and minimum time is 32 seconds, default tick is 4 (32 seconds).
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" instance="1" index="10" genre="config" label="10. Auto Report Battery Time" units="30 min" min="1" max="127" value="12">
|
|
<Help>
|
|
The interval time for auto report the battery level.
|
|
30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours)
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" instance="1" index="12" genre="config" label="12. Auto Report Illumination Time" units="30 min" min="1" max="127" value="12">
|
|
<Help>
|
|
The interval time for auto report the illumination.
|
|
30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours)
|
|
</Help>
|
|
</Value>
|
|
|
|
<Value type="byte" instance="1" index="13" genre="config" label="13. Auto Report Temperature time" units="30 min" min="1" max="127" value="12">
|
|
<Help>
|
|
The interval time for auto report the temperature.
|
|
30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours)
|
|
</Help>
|
|
</Value>
|
|
|
|
</CommandClass>
|
|
|
|
<!-- Basic set as report -->
|
|
<!-- <CommandClass id="32" setasreport="true" ignoremapping="true"/> -->
|
|
|
|
<CommandClass id="48" create_vars="false">
|
|
<Instance index="1" />
|
|
<Value type="bool" genre="user" instance="1" index="0" label="Motion Sensor" read_only="true" write_only="false" min="0" max="0" value="false" />
|
|
<Value type="bool" genre="user" instance="1" index="1" label="Door/Window Sensor" read_only="true" write_only="false" value="false" />
|
|
<Value type="bool" genre="user" instance="1" index="2" label="Tamper Sensor" read_only="true" write_only="false" min="0" max="0" value="false" />
|
|
<SensorMap index="0" type="12" />
|
|
<SensorMap index="1" type="10" />
|
|
<SensorMap index="2" type="8" />
|
|
</CommandClass>
|
|
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="2">
|
|
<Group index="1" max_associations="7" label="Report message" auto="true"/>
|
|
<Group index="2" max_associations="7" label="Light control" auto="true"/>
|
|
</Associations>
|
|
</CommandClass>
|
|
|
|
</Product> |