hal/plugins/hal-zwave/resources/config/horstmann/hrt4zw.xml

48 lines
1.7 KiB
XML

<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- The thermostat does not properly report its operating modes -->
<CommandClass id="64">
<SupportedModes>
<Mode index="0" label="Off" />
<Mode index="1" label="Heat" />
</SupportedModes>
</CommandClass>
<!-- This thermostat's setpoint descriptions are 0 based, not 1 -->
<CommandClass id="67" base="0" />
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="byte" index="1" genre="config" label="Enable Temperature sensor reading" value="0">
<Help>
0-127 = Disabled.
128-255 = Enabled.
</Help>
</Value>
<Value type="byte" index="2" genre="config" label="Temperature Scale" value="0">
<Help>
0-127 = Celsius.
128-255 = Fahrenheit.
</Help>
</Value>
<Value type="byte" index="3" genre="config" label="Temperature Delta T" value="10">
<Help>
Delta T in steps of 0.1 degree.
</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<!-- Groups and attributes based on http://www.pepper1.net/zwavedb/device/59 -->
<Associations num_groups="1">
<Group index="1" max_associations="4" label="Thermostat Mode Set" auto="true"/>
<Group index="2" max_associations="4" label="Binary Switch Set" auto="true"/>
<Group index="3" max_associations="4" label="Unsolicited Battery Level Reports" auto="true"/>
<Group index="4" max_associations="4" label="Thermostat Set Point Reports" auto="true"/>
<Group index="5" max_associations="4" label="Unsolicited Sensor Multilevel Reports" auto="true"/>
</Associations>
</CommandClass>
</Product>