35 lines
1.4 KiB
XML
35 lines
1.4 KiB
XML
<?xml version="1.0" encoding="utf-8"?>
|
|
<!-- EVERSPRING AN158 ON/OFF MODULE -->
|
|
<!-- Information from http://www.pepper1.net/zwavedb/device/54 -->
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!-- Configuration Parameters -->
|
|
<CommandClass id="112">
|
|
<Value type="short" index="1" genre="config" label="True Period" units="100ms" min="0" max="120" value="10">
|
|
<Help>
|
|
This is the time the switching status needs to remain
|
|
unchanged after a change to cause the device to send out a status
|
|
message. 0 is Disabled.
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" index="2" genre="config" label="Send Out Basic Command" units="" min="0" max="1" value="0">
|
|
<Help>
|
|
Enable or Disable Send Basic Command to Group 2 when the local
|
|
button press changes the switching state.
|
|
</Help>
|
|
</Value>
|
|
<Value type="short" index="3" genre="config" label="Meter Report Period" units="10s" min="0" max="3240" value="3">
|
|
<Help>
|
|
The device will report its meter value within the interval
|
|
set. Set to 0 will disable the autoreporting function.
|
|
</Help>
|
|
</Value>
|
|
</CommandClass>
|
|
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="2">
|
|
<Group index="1" max_associations="1" label="Reports" auto="true" />
|
|
<Group index="2" max_associations="4" label="Basic" auto="true" />
|
|
</Associations>
|
|
</CommandClass>
|
|
</Product>
|