<?xml version="1.0" encoding="utf-8"?>
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!-- Configuration Parameters -->
|
|
<CommandClass id="112">
|
|
<Value type="list" index="2" genre="config" label="Reverse Clamping" units="" min="0" max="1" value="0" size="1">
|
|
<Help>
|
|
If the reverse clamping pliers, negative power is detected.
|
|
</Help>
|
|
<Item label="Disable" value="0" />
|
|
<Item label="Enable" value="1" />
|
|
</Value>
|
|
<Value type="list" index="3" genre="config" label="Power changed" units="" min="0" max="1" value="0" size="1">
|
|
<Help>
|
|
Automatic report only when power is changed.
|
|
</Help>
|
|
<Item label="Disable" value="0" />
|
|
<Item label="Enable" value="1" />
|
|
</Value>
|
|
<Value type="short" index="4" genre="config" label="Wattage Threshold" units="watts" value="50">
|
|
<Help>
|
|
Threshold change in wattage to induce a automatic report (whole HEM).
|
|
</Help>
|
|
</Value>
|
|
<Value type="short" index="5" genre="config" label="Wattage Threshold C1" units="watts" value="50">
|
|
<Help>
|
|
Threshold change in wattage to induce a automatic report (Clamp 1).
|
|
</Help>
|
|
</Value>
|
|
<Value type="short" index="6" genre="config" label="Wattage Threshold C2" units="watts" value="50">
|
|
<Help>
|
|
Threshold change in wattage to induce a automatic report (Clamp 2).
|
|
</Help>
|
|
</Value>
|
|
<Value type="short" index="7" genre="config" label="Wattage Threshold C3" units="watts" value="50">
|
|
<Help>
|
|
Threshold change in wattage to induce a automatic report (Clamp 3).
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" index="8" genre="config" label="Wattage Percentage Change" units="%" value="10">
|
|
<Help>
|
|
Percentage change in wattage to induce a automatic report (whole HEM).
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" index="9" genre="config" label="Wattage Percentage Change C1" units="%" value="10">
|
|
<Help>
|
|
Percentage change in wattage to induce a automatic report (Clamp 1).
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" index="10" genre="config" label="Wattage Percentage Change C2" units="%" value="10">
|
|
<Help>
|
|
Percentage change in wattage to induce a automatic report (Clamp 2).
|
|
</Help>
|
|
</Value>
|
|
<Value type="byte" index="11" genre="config" label="Wattage Percentage Change C3" units="%" value="10">
|
|
<Help>
|
|
Percentage change in wattage to induce a automatic report (Clamp 3).
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="100" genre="config" label="Reset #101-103" units="" value="0" write_only="true" affects="101,102,103">
|
|
<Help>
|
|
Reset to default parameters number 101-103. Any value other then 0 will initiate this reset.
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="101" genre="config" label="Group 1 Reports" units="" value="0">
|
|
<Help>
|
|
Which reports need to send in group1. Format is as follows:
|
|
Byte 1 (msb): Reserved
|
|
Byte 2: Reserved
|
|
Byte 3: Bit 7: reserved
|
|
Bit 6: reserved
|
|
Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3)
|
|
Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2)
|
|
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1)
|
|
Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3)
|
|
Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2)
|
|
Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1)
|
|
Byte 4 (lsb): Bit 7: reserved
|
|
Bit 6: reserved
|
|
Bit 5: reserved
|
|
Bit 4: reserved
|
|
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM)
|
|
Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM)
|
|
Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM)
|
|
Bit 0: Auto Send Battery Report at the group time interval (whole HEM)
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="102" genre="config" label="Group 2 Reports" units="" value="0">
|
|
<Help>
|
|
Which reports need to send in group2. Format is as follows:
|
|
Byte 1 (msb): Reserved
|
|
Byte 2: Reserved
|
|
Byte 3: Bit 7: reserved
|
|
Bit 6: reserved
|
|
Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3)
|
|
Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2)
|
|
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1)
|
|
Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3)
|
|
Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2)
|
|
Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1)
|
|
Byte 4 (lsb): Bit 7: reserved
|
|
Bit 6: reserved
|
|
Bit 5: reserved
|
|
Bit 4: reserved
|
|
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM)
|
|
Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM)
|
|
Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM)
|
|
Bit 0: Auto Send Battery Report at the group time interval (whole HEM)
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="103" genre="config" label="Group 3 Reports" units="" value="0">
|
|
<Help>
|
|
Which reports need to send in group3. Format is as follows:
|
|
Byte 1 (msb): Reserved
|
|
Byte 2: Reserved
|
|
Byte 3: Bit 7: reserved
|
|
Bit 6: reserved
|
|
Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3)
|
|
Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2)
|
|
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1)
|
|
Bit 2: Auto Send Meter Report (for watts) at the group time interval (Clamp 3)
|
|
Bit 1: Auto Send Meter Report (for watts) at the group time interval (Clamp 2)
|
|
Bit 0: Auto Send Meter Report (for watts) at the group time interval (Clamp 1)
|
|
Byte 4 (lsb): Bit 7: reserved
|
|
Bit 6: reserved
|
|
Bit 5: reserved
|
|
Bit 4: reserved
|
|
Bit 3: Auto Send Meter Report (for kWh) at the group time interval (whole HEM)
|
|
Bit 2: Auto Send Meter Report (for watts) at the group time interval (whole HEM)
|
|
Bit 1: Auto Send Multilevel Sensor Report (for watts) at the group time interval (whole HEM)
|
|
Bit 0: Auto Send Battery Report at the group time interval (whole HEM)
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="110" genre="config" label="Reset #111-113" units="" value="0" write_only="true" affects="111,112,113">
|
|
<Help>
|
|
Reset to default parameters number 111-113. Any value other then 0 will initiate this reset.
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="111" genre="config" label="Group 1 Interval" units="seconds" value="720">
|
|
<Help>
|
|
The interval of sending report group 1.
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="112" genre="config" label="Group 2 Interval" units="seconds" value="720">
|
|
<Help>
|
|
The interval of sending report group 2.
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="113" genre="config" label="Group 3 Interval" units="seconds" value="720">
|
|
<Help>
|
|
The interval of sending report group 3.
|
|
</Help>
|
|
</Value>
|
|
<Value type="list" index="200" genre="config" label="Partner ID" units="" min="0" max="1" size="1" value="0">
|
|
<Item label="Aeon Labs Standard Product" value="0" />
|
|
<Item label="AT&T" value="1" />
|
|
</Value>
|
|
<Value type="short" index="254" genre="config" label="Device Tag" units="" value="0">
|
|
<Help>
|
|
Device tag.
|
|
</Help>
|
|
</Value>
|
|
<Value type="int" index="255" genre="config" label="Reset default configuration" units="" value="0" write_only="true" affects="all">
|
|
<Help>
|
|
Reset to the default configuration.
|
|
</Help>
|
|
</Value>
|
|
</CommandClass>
|
|
|
|
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="1">
|
|
<Group index="1" max_associations="5" label="Report" auto="true" />
|
|