<?xml version="1.0" encoding="utf-8"?>
<!-- Aeon Labs Recessed Door Sensor -->
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration -->
<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="1" label="Toggle the sensor binary report value when the Magnet switch is opened/closed." min="0" max="1" value="0">
<Help>0, Open: FF, Close: 00; 1, Open: 00, Close: FF;
Default setting: 0
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="Toggle the basic set value when Magnet switch is opened/closed." min="0" max="1" value="0">
<Help>0, Open: FF, Close: 00; 1, Open: 00, Close: FF;
Default setting: 0
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="101" label="If battery power is below the warning value, low battery checking function will be triggered and Low Battery Warning Report will be sent." min="0" max="1" value="0">
<Help>0, Disable, 1, Enable;
Default setting: 0
</Help>
</Value>
<Value type="int" genre="config" instance="1" index="111" label="The low battery check Interval time,0-4294967295 seconds." min="0" max="1" value="86640">
<Help>This parameter is available when the low battery checking
function is activated or the device was waked up by other
actions (i.e. the z-wave button trigger, magnet switch
trigger and the Wake Up Interval Set timeout trigger).
The Recessed Door Sensor will check the battery power
when it was wake up as other ways. For example: the
z-wave button trigger, magnet switch trigger and the
Wake Up Interval Set timeout trigger.
Default setting: 86640
</Help>
</Value>
<Value type="int" genre="config" instance="1" index="121" label="Flag values for which reports to send when the Magnet of Recessed Door Sensor is triggered." min="0" max="1" value="256">
<Help>Bitsets:
4 -> Sensor Binary
8 -> Basic Set
Default setting: 0x00000100 (Basic Set)
</Help>
</Value>
<Value type="short" index="254" genre="config" label="Device Tag" units="" min="0" max="255" value="0">
<Help>Device Tag</Help>
</Value>
<Value type="button" index="255" genre="config" label="Reset configuration settings to factory defaults" write_only="true" value="0" >
<Help>Reset to factory defaults.</Help>
</Value>
</CommandClass>
<!-- Basic set as report -->
<CommandClass id="32" setasreport="true"/>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="2">
<Group index="1" max_associations="5" label="Group 1: Will receive Basic Set/ Sensor Binary Report (configurable) when the status of Recessed Door Sensors magnet switch open or close." auto="false"/>
<Group index="2" max_associations="5" label="Group 2: If the battery power is below the warning value, the Node IDs in Group 2 will receive the Low Battery Warning Report, and when the Recessed Door Sensor wake up at the first time it will receive the Battery Report." auto="false"/>
</Associations>
</CommandClass>