<?xml version="1.0" encoding="utf-8"?>
|
|
<!--Taken from http://en.z-wave.me/docs/ZME_0643x_UserManual.pdf-->
|
|
<Product xmlns='http://code.google.com/p/open-zwave/'>
|
|
<!-- Configuration Parameters -->
|
|
<!--IMPORTANT: Controllers may only allow to configure signed values.
|
|
In order to set values in the range 128?255 for parameters 4, 5 and 6 the
|
|
value sent in the application shall be the desired value minus 256.
|
|
For example: to set parameter 4 in Window Blind to 200? sit may be needed
|
|
to set a value of 200?256=?56.
|
|
Similar rule applies to parameter 2: to set values in range 32768?65535
|
|
use value equal to desired value minus 65536. For example, to set auto
|
|
switch off period to 10 hours =36000s it may be needed to set a value
|
|
36000?65536=?29536.-->
|
|
|
|
<CommandClass id="112">
|
|
<Value type="list" index="1" genre="config" label="Set LED indication mode" units="" min="1" max="99" value="3" size="1">
|
|
<Item label="Disabled" value="0" />
|
|
<Item label="Show switch/dimmer state / when in motion or inactive (for blinds)" value="1" />
|
|
<Item label="Night mode (inverted switch state)" value="2" />
|
|
<Item label="Operated by Indicator Command Class (default)" value="3" />
|
|
<Item label="Show if not closed (for blinds only)" value="4" />
|
|
</Value>
|
|
<Value type="int" index="2" genre="config" label="Automatically open or close after" units="seconds" min="0" max="65535" value="0">
|
|
<Help>If not zero, automatically switch off/close blind after a user defined time</Help>
|
|
</Value>
|
|
<Value type="list" index="3" genre="config" label="What to do on RF off command" value="0" size="1">
|
|
<Help>If not zero, automatically switch off/close blind after a user defined time</Help>
|
|
<Item label="Switch off (default)" value="0" />
|
|
<Item label="Ignore" value="1" />
|
|
<Item label="Switch on" value="2" />
|
|
</Value>
|
|
<Value type="byte" index="4" genre="config" label="Full close time" units="Second" min="0" max="255" value="60" size="1">
|
|
<Help>Time to go from opened to closed state. Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and Multilevel Set values (1-99, 255) would Open except 0 value that would Close.</Help>
|
|
</Value>
|
|
<Value type="byte" index="5" genre="config" label="Full open time" units="Second" min="0" max="255" value="60" size="1">
|
|
<Help>Time to go from closed to open state. This value may differ from Full close time for some blinds due to gravity. Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and Multilevel Set values (1-99, 255) would Open except 0 value that would Close.</Help>
|
|
</Value>
|
|
<Value type="byte" index="6" genre="config" label="Node Id of the blocking device" min="0" max="232" value="0">
|
|
<Help>Id of the device which commands would be interpreted not as Open/Close, but as block/unblock. Usefull with door opening detector: if the door is open, block the blind not to break shades while they move.</Help>
|
|
</Value>
|
|
<Value type="list" index="7" genre="config" label="On which command from blocking node to enable the protection" min="0" max="1" value="0" size="1">
|
|
<Help>Defines which command from blocking device to interpret as closed door and hence, unprotected.</Help>
|
|
<Item label="on On (default)" value="0" />
|
|
<Item label="on Off" value="1" />
|
|
</Value>
|
|
<Value type="list" index="8" genre="config" label="Stop or Revert if opposite button is pressed" units="" min="0" max="2" value="0">
|
|
<Help>Defines behaviour on open press while closing and vice versa. To allow Stop behavior when switched by remote, use Stop by Basic</Help>
|
|
<Item label="Stop (by buttons and Binary) (Default)" value="0" />
|
|
<Item label="Stop (by buttons, Binary and Basic)" value="1" />
|
|
<Item label="Revert" value="2" />
|
|
</Value>
|
|
<Value type="list" index="9" genre="config" label="Invert open and close relays" units="" min="0" max="1" value="0">
|
|
<Help>Allow exchanging open and close relays if blind control is wired to the motor incorrectly</Help>
|
|
<Item label="No (default)" value="0" />
|
|
<Item label="Yes" value="1" />
|
|
</Value>
|
|
<Value type="byte" index="10" genre="config" label="Typical click timeout" units="x 10 milliseconds" min="1" max="100" value="50">
|
|
<Help>Typical time used to differentiate click, hold, double and triple clicks.</Help>
|
|
</Value>
|
|
<Value type="list" index="11" genre="config" label="Invert buttons" value="0" size="1">
|
|
<Item label="No default)" value="0" />
|
|
<Item label="Yes" value="1" />
|
|
</Value>
|
|
<Value type="list" index="12" genre="config" label="Switch by buttons" value="1" size="1">
|
|
<Help>If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only. </Help>
|
|
<Item label="No" value="0" />
|
|
<Item label="By single press and hold (default)" value="1" />
|
|
<Item label="By double press and hold" value="1" />
|
|
</Value>
|
|
<Value type="list" index="13" genre="config" label="Action on button single press or hold" value="1" size="1">
|
|
<Help>Defines which command should be sent on button single press or hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. </Help>
|
|
<Item label="Disabled" value="0" />
|
|
<Item label="Switch On, Off and dim using Basic Set(default)" value="1" />
|
|
<Item label="Switch All On/Off" value="1" />
|
|
</Value>
|
|
<Value type="list" index="13" genre="config" label="Action on button double press or hold" value="0" size="1">
|
|
<Help>Defines which command should be sent on button double press or press-hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands.</Help>
|
|
<Item label="Disabled (don't wait for double click,default)" value="0" />
|
|
<Item label="Switch On, Off and dim using Basic Set" value="1" />
|
|
<Item label="Switch All On/Off" value="1" />
|
|
</Value>
|
|
<Value type="list" index="15" genre="config" label="Send the following Switch All commands" value="1" size="1">
|
|
<Item label="Switch All Off only (default)" value="1" />
|
|
<Item label="Switch All On only" value="1" />
|
|
<Item label="Switch All On and Off" value="255" />
|
|
</Value>
|
|
</CommandClass>
|
|
|
|
<!-- Association Groups -->
|
|
<CommandClass id="133">
|
|
<Associations num_groups="3">
|
|
<Group index="1" max_associations="8" label="Group 1" auto="false"/>
|
|
<Group index="2" max_associations="8" label="Group 2" auto="false" />
|
|
<Group index="3" max_associations="8" label="Send updates" auto="true"/>
|
|
</Associations>
|
|
</CommandClass>
|
|
</Product>
|