Stay awake for 10 minutes after batteries are inserted
0 -> No
1 -> Yes
How long should the device associated to multi sensor keep
state On before sending it Off command (if the value is bigger
than 255, the value would be rounded to next integer in minutes)
Enable Motion Sensor
0 -> Disabled
1 -> Enabled
Which commands to send when PIR motion sensor triggered
1 (default) -> Basic Set
2 -> Binary Sensor Report
Reset to default parameters number 101-103. Any value other then 0 will initiate this reset.
Which reports need to send automatically in timing intervals for group 1
Bitsets:
0 -> Battery report
5 -> Temperature
6 -> Humidity
7 -> Luminosity
Which reports need to send automatically in timing intervals for group 2
Bitsets:
0 -> Battery report
5 -> Temperature
6 -> Humidity
7 -> Luminosity
Which reports need to send automatically in timing intervals for group 3
Bitsets:
0 -> Battery report
5 -> Temperature
6 -> Humidity
7 -> Luminosity
Reset to default parameters number 111-113. Any value other then 0 will initiate this reset.
The interval of sending report group 1.
1 seconds - 2678400 seconds
The interval of sending report group 2.
1 seconds - 2678400 seconds
The interval of sending report group 3.
1 seconds - 2678400 seconds
Reset to factory defaults.